Meet your regulatory needs with technology that is ideal for a wide range of applications and advanced dissolved oxygen analysis in the lab. Orion advanced and premium benchtop meters offer the flexibility to measure both polargraphic and optical technology. A dedicated kit, complete with BOD stirrer probe needed to fit in a DO bottle for airtight incubation, is available with the Orion Star A213 meter.
Calibrate using water-saturated air, air-saturated water, or custom value, using Winkler titration or zero point options. Log up to 2,000 data point sets with time/date stamp, and easily transfer calibration and data logs via USB or RS232 to a printer or computer when using an Orion advanced or premium dissolved oxygen meter.
Select your dissolved oxygen bench or portable meters
- Orion Bench Meters
- Orion Portable Meters
- Eutech Bench Meters
- Eutech Portable Meters
Premium | Advanced | Basic | |
---|---|---|---|
Orion Versa Star Pro RDO/DO (VSTAR30series) | Orion Star A213 RDO/DO (STARA2130 series) | Orion Lab Star DO113 DO (Lab Star series) | |
Versatile, high-performance laboratory measurement system | Easy-to-use, dependable laboratory meters | Economical, simplified laboratory meters | |
Ideal for applications in: | Pharmaceuticals, biotechnology, food and beverage, industrial | Water, wastewater, chemical, contract testing | Academic, environmental, power |
Compatible probes | Optical, polarographic | Optical, polarographic | Polarographic |
DO range (polarographic) | 0 to 90 mg/L, 0 to 600% | 0 to 90 mg/L, 0 to 600% | 0 to 30 mg/L, 0 to 300% |
DO range (RDO optical) | 0 to 50 mg/L, 0 to 500% | 0 to 50 mg/L, 0 to 500% | --- |
DO calibration modes | Water-saturated air, air-saturated water, manual (Winkler), zero point | Water-saturated air, air-saturated water, manual (Winkler), zero point | 100% and 0% saturation; custom concentration value |
Barometric pressure compensation | Automatic with built-in barometer | Automatic with built-in barometer | Automatic with manual value input |
Salinity correction | Automatic with conductivity module and probe or manual input | Automatic with manual factor input | Automatic with manual factor input |
Backlit display | Yes | Yes | Yes |
Number of channels | 4, customizable with modules | 1 | 1 |
Stirrer probe inputs | 2 | 1 | --- |
Data log | 2,000 with date/time | 2,000 with date/time | 500 sets with date/time |
Calibration log | 30 per mode | 10 | 1 |
Identification options | Electrode ID, sample ID, user ID | Sample ID, user ID | --- |
Data export output | Computer or printer | Computer or printer | Computer or printer |
Power supply | Universal, 1000150–240 VAC, 50–60 Hz (Cat. No. STARA-PWR) | Universal, 100–240 VAC, 50–60 Hz (Cat. No. 1010003) or 4 AA batteries | Universal, 100–240 VAC, 50–60 Hz (Cat. No. LSTAR-PWR), 9DC adapter, 1.3A |
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories › |
Premium | Advanced | Basic | |
---|---|---|---|
Orion Star A323 Dissolved Oxygen (STARA3230 series) | Orion Star A223 Dissolved Oxygen (STARA2230 series) | Orion Star A123 Dissolved Oxygen (STARA1230 series) | |
Compatible probes | RDO, polarographic | RDO, polarographic | Polarographic |
DO range (polarographic) | 0 to 600% saturation | 0 to 600% saturation | 0 to 200% Saturation |
DO range (RDO optical) | 0 to 50 mg/L | 0 to 50 mg/L | --- |
DO calibration modes | Water-saturated air, air saturated water, manual (Winkler), and zero point | Water-saturated air, air saturated water, manual (Winkler), and zero point | Water-saturated air, manual (Winkler) |
Barometric pressure compensation | 400 to 850 mmHg, automatic or manual | 400 to 850 mmHg, automatic or manual | --- |
Salinity Correction | 0 to 45 ppt | 0 to 45 ppt | 0 to 45 |
Backlit Display | Yes | Yes | --- |
Number of channels | 1 | 1 | 1 |
Data log | 5000 with time and date stamp | 1000 with time and date stamp | 50 |
Data export options | RS232,USB | RS232, USB | RS232, USB |
AC Adapter | Optional—universal, 100-240 VAC | Optional—universal, 100-240 VAC | Optional—universal, 100-240 VAC |
Battery power | Included—4AA's | Included—4AA's | Included—4AA's |
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories › |
Advanced | Basic | |
---|---|---|
Eutech DO2700 Dissolved Oxygen Bench Meter | Eutech 1730 Dissolved Oxygen Bench Meter | |
Economical, routine laboratory meters | Budget-friendly, simple laboratory meters | |
Compatible probes | Polarographic | Galvanic |
DO range (Polarographic) | 0.00 to 50.00 mg/L; 0 to 600.0 % saturation | --- |
DO range (Galvanic) | --- | 0 to 30 mg/L; 0 to 300.0 % saturation |
DO calibration modes | Water-saturated air, zero point, manual (Winkler) | 100% and 0% saturation, manual concentration value (Winkler) |
Barometric pressure compensation | Automatic with built-in barometer | Automatic with manual value entry |
Salinity correction | Automatic with manual value entry | Automatic with manual value entry |
Range (temperature) | 0.0 to 50.0 °C, 32.0 to 122.0 °F | -5.0 to 105.0 ºC |
Backlit display | Yes | Yes |
Number of channels | 1 | 1 |
Stirrer probe inputs | Yes | --- |
Data log | 500 with date/time | 500 with date/time |
Calibration log | Most recent viewable on meter and stored in meter memory | Active dissolved oxygen, temperature with time and date |
Data export options | RS232 | Computer or printe |
Power supply | Universal, 100-240VAC, 50/60 Hz, Cat. No. 60X426401 | Universal, 100–240VAC, 50–60Hz (Cat. No. EB1700PWR), 9 DC adapter, 1.3A |
").addClass("unsuppported-videoplayer").insertAfter($(".brightcoveplayer, .cmp-p-videoplayer"));}
Watch and learn more:
Features & Benefits of the Eutech 1730 Dissolved Oxygen Bench Meter
Premium | Advanced | Basic | |
---|---|---|---|
Eutech DO 450 Portable Dissolved Oxygen Meter | Eutech DO 600 Portable Dissolved Oxygen Meter | Eutech DO 6+ Portable Dissolved Oxygen Meter | |
Compatible probes | RDO | Polorographic | Polorographic |
DO range (polarographic) | --- | 0 to 90.00 mg/L or ppm | 0.00 to 19.99 mg/L or ppm |
DO range (RDO optical) | 0 to 200 %; 0 to 20 ppm/mg/L | --- | --- |
DO calibration modes | Zero and saturation | 2-point (0 %, 100 %), 1-point (mg/L) | 2-point (0 %, 100 %), 1-point (mg/L) |
Barometric pressure compensation | Manual | 450 to 825 mmHg / 59.9 to 109.9 kPa | 500 to 1499 mmHg / 66.6 to 199.9 kPa (Manual Input) |
Salinity correction | Manual | 0.0 to 50.0 ppt (Manual Input) | 0.0 to 50.0 ppt (Manual Input) |
Backlit display | Yes | Yes | --- |
Number of channels | 1 | 1 | 1 |
Data log | 500 with time and date stamp | 500 with time and date stamp | --- |
Data export options | USB or RS232 | IrDA, RS232C (via LED) | --- |
AC adapter | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) (optional) | 9 V DC adapter | --- |
Battery power | Two AA batteries (included) | Included—4AAs | 4 x AAA batteries |
Orion Bench Meters
Premium | Advanced | Basic | |
---|---|---|---|
Orion Versa Star Pro RDO/DO (VSTAR30series) | Orion Star A213 RDO/DO (STARA2130 series) | Orion Lab Star DO113 DO (Lab Star series) | |
Versatile, high-performance laboratory measurement system | Easy-to-use, dependable laboratory meters | Economical, simplified laboratory meters | |
Ideal for applications in: | Pharmaceuticals, biotechnology, food and beverage, industrial | Water, wastewater, chemical, contract testing | Academic, environmental, power |
Compatible probes | Optical, polarographic | Optical, polarographic | Polarographic |
DO range (polarographic) | 0 to 90 mg/L, 0 to 600% | 0 to 90 mg/L, 0 to 600% | 0 to 30 mg/L, 0 to 300% |
DO range (RDO optical) | 0 to 50 mg/L, 0 to 500% | 0 to 50 mg/L, 0 to 500% | --- |
DO calibration modes | Water-saturated air, air-saturated water, manual (Winkler), zero point | Water-saturated air, air-saturated water, manual (Winkler), zero point | 100% and 0% saturation; custom concentration value |
Barometric pressure compensation | Automatic with built-in barometer | Automatic with built-in barometer | Automatic with manual value input |
Salinity correction | Automatic with conductivity module and probe or manual input | Automatic with manual factor input | Automatic with manual factor input |
Backlit display | Yes | Yes | Yes |
Number of channels | 4, customizable with modules | 1 | 1 |
Stirrer probe inputs | 2 | 1 | --- |
Data log | 2,000 with date/time | 2,000 with date/time | 500 sets with date/time |
Calibration log | 30 per mode | 10 | 1 |
Identification options | Electrode ID, sample ID, user ID | Sample ID, user ID | --- |
Data export output | Computer or printer | Computer or printer | Computer or printer |
Power supply | Universal, 1000150–240 VAC, 50–60 Hz (Cat. No. STARA-PWR) | Universal, 100–240 VAC, 50–60 Hz (Cat. No. 1010003) or 4 AA batteries | Universal, 100–240 VAC, 50–60 Hz (Cat. No. LSTAR-PWR), 9DC adapter, 1.3A |
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories › |
Orion Portable Meters
Premium | Advanced | Basic | |
---|---|---|---|
Orion Star A323 Dissolved Oxygen (STARA3230 series) | Orion Star A223 Dissolved Oxygen (STARA2230 series) | Orion Star A123 Dissolved Oxygen (STARA1230 series) | |
Compatible probes | RDO, polarographic | RDO, polarographic | Polarographic |
DO range (polarographic) | 0 to 600% saturation | 0 to 600% saturation | 0 to 200% Saturation |
DO range (RDO optical) | 0 to 50 mg/L | 0 to 50 mg/L | --- |
DO calibration modes | Water-saturated air, air saturated water, manual (Winkler), and zero point | Water-saturated air, air saturated water, manual (Winkler), and zero point | Water-saturated air, manual (Winkler) |
Barometric pressure compensation | 400 to 850 mmHg, automatic or manual | 400 to 850 mmHg, automatic or manual | --- |
Salinity Correction | 0 to 45 ppt | 0 to 45 ppt | 0 to 45 |
Backlit Display | Yes | Yes | --- |
Number of channels | 1 | 1 | 1 |
Data log | 5000 with time and date stamp | 1000 with time and date stamp | 50 |
Data export options | RS232,USB | RS232, USB | RS232, USB |
AC Adapter | Optional—universal, 100-240 VAC | Optional—universal, 100-240 VAC | Optional—universal, 100-240 VAC |
Battery power | Included—4AA's | Included—4AA's | Included—4AA's |
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories › |
Eutech Bench Meters
Advanced | Basic | |
---|---|---|
Eutech DO2700 Dissolved Oxygen Bench Meter | Eutech 1730 Dissolved Oxygen Bench Meter | |
Economical, routine laboratory meters | Budget-friendly, simple laboratory meters | |
Compatible probes | Polarographic | Galvanic |
DO range (Polarographic) | 0.00 to 50.00 mg/L; 0 to 600.0 % saturation | --- |
DO range (Galvanic) | --- | 0 to 30 mg/L; 0 to 300.0 % saturation |
DO calibration modes | Water-saturated air, zero point, manual (Winkler) | 100% and 0% saturation, manual concentration value (Winkler) |
Barometric pressure compensation | Automatic with built-in barometer | Automatic with manual value entry |
Salinity correction | Automatic with manual value entry | Automatic with manual value entry |
Range (temperature) | 0.0 to 50.0 °C, 32.0 to 122.0 °F | -5.0 to 105.0 ºC |
Backlit display | Yes | Yes |
Number of channels | 1 | 1 |
Stirrer probe inputs | Yes | --- |
Data log | 500 with date/time | 500 with date/time |
Calibration log | Most recent viewable on meter and stored in meter memory | Active dissolved oxygen, temperature with time and date |
Data export options | RS232 | Computer or printe |
Power supply | Universal, 100-240VAC, 50/60 Hz, Cat. No. 60X426401 | Universal, 100–240VAC, 50–60Hz (Cat. No. EB1700PWR), 9 DC adapter, 1.3A |
").addClass("unsuppported-videoplayer").insertAfter($(".brightcoveplayer, .cmp-p-videoplayer"));}
Watch and learn more:
Features & Benefits of the Eutech 1730 Dissolved Oxygen Bench Meter
Eutech Portable Meters
Premium | Advanced | Basic | |
---|---|---|---|
Eutech DO 450 Portable Dissolved Oxygen Meter | Eutech DO 600 Portable Dissolved Oxygen Meter | Eutech DO 6+ Portable Dissolved Oxygen Meter | |
Compatible probes | RDO | Polorographic | Polorographic |
DO range (polarographic) | --- | 0 to 90.00 mg/L or ppm | 0.00 to 19.99 mg/L or ppm |
DO range (RDO optical) | 0 to 200 %; 0 to 20 ppm/mg/L | --- | --- |
DO calibration modes | Zero and saturation | 2-point (0 %, 100 %), 1-point (mg/L) | 2-point (0 %, 100 %), 1-point (mg/L) |
Barometric pressure compensation | Manual | 450 to 825 mmHg / 59.9 to 109.9 kPa | 500 to 1499 mmHg / 66.6 to 199.9 kPa (Manual Input) |
Salinity correction | Manual | 0.0 to 50.0 ppt (Manual Input) | 0.0 to 50.0 ppt (Manual Input) |
Backlit display | Yes | Yes | --- |
Number of channels | 1 | 1 | 1 |
Data log | 500 with time and date stamp | 500 with time and date stamp | --- |
Data export options | USB or RS232 | IrDA, RS232C (via LED) | --- |
AC adapter | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) (optional) | 9 V DC adapter | --- |
Battery power | Two AA batteries (included) | Included—4AAs | 4 x AAA batteries |